<LOGO>
FM Transmitter Measurement Report
Created: 2025-04-12 12-55-19
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 5/5, 56 dBuV VOLTAGE
Pilot RDS Phase Difference
6.5 kHz 4.1 kHz -11 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 71 kHz 10020 0,4391
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
6,6 dBr 7,53 dBr 8,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 12:55, 12.04.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 5/5 (55 dBuV) Max at: 71 kHz MIN: 11 kHz % above 76 kHz: 0,4391 Acquired: 2025/04/12 12:54:15 Total samples: 10020 Equivalent time: 0:08:21 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 8,2 dBr MIN: 6,6 dBr AVE: 7,53 dBr % above 10,2 dBr: 0,0 Last value: 7,8 dBr (2025/04/12 12:54:15) Station: 96.90 MHz, signal: 4/5 (54 dBuV) 12:47 12:48 12:49 12:50 12:51 12:52 12:53 12:54 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality